GC8 indicator wiring for keyless entry install
Hey all,
Been searching high n low for help doing the final bit of my keyless entry kit install. Got the single-wire central locking of the GC8 sussed but haven't found a way to wire up the indicators so they flash when I lock/unlock. Anyone done this? I've been trying to figure out the hazard light connector. It's got 8 wires but not sure if I can get away with splicing one wire with the signal from the keyless entry or if I'll need to grab some relays/diodes to wire up to each side...? |
Nevermind, found a wiring diagram for the hazards and it was pretty straight forward to hook up a relay and the two indicator wires once I found them.
FYI the top two right ones on the connector (3,4) are the indicators and you can use the bottom right wire (1 = white) for the 12V power to the relay... |